ROLL TESTER

Function
- Hot & Cold rolling roll inspection system
- Using the UT surface wave probe & ECT rotating (or Array) probe
- Detecting the surface flaw in roll after grinding
- Optional internal flaw testing using UT straight beam probe
PERFORMANCE
- Guiding
- Contact or Non-contact
- Flaw
- Surface & subsurface flaw
- Test Method
-
UT : Surface wave probe (2.25 MHz)
Optional straight beam probe
ECT : Rotating probe (15,000RPM)
- Roll type
- Rolls for hot rolling and cold rolling HSS, Hi-Cr and others
- Flaw Detectability
- 0.1mm(D) x 0.1mm(W) x 2mm(L)